@ X-ray Optical Stage

-     Radiation protected cabinet combined with safety electronics and power supply;

-     Newport optical table;

-     Radiation sources: X-ray tubes:
-     X-ray tube Oxford Apogee Cu con housing;
-     X-ray tube Oxford Apogee Mo con housing;
-     X-ray tube Oxford Apogee W con housing;
-     compact X-ray tube Unisantis Mo con housing
-     Detector units:
-     Scintillator Saint-Gobain (scintillator with an effective working area of  1 in2);
-     CCD Photonic Science FDI 1.61:1 with the software package ``Image Pro'' for X-ray fine imaging: sensitive area of 4x3 mm2 with a 3.5x3.5 µm2 resolution;
-     CCD Photonic Science FDI 1:1.61 with the software package ``Image Pro'' for X-ray rough imaging an active area of 14.4x10.8 mm2 with a resolution of 10.4x10.4 µm2;
-     SDD XGLab silicon drift detector with a 5 mm2 working area;
-     CCD Experiment “Dear” (loan by group “Siddharta”)
-     Optics
-     Full Lens (Uns1g-11-041004) – arrivata a febbraio
-     Full Lens  – viene da Unisantid Gmbh
-     Half Lens (Uns1g-2f-041205) – arivata a febbraio
-     G-lens (Uns1g-2-220407) – arrivata a febbraio
-     4 Cylindrical Polycapillary Optics – arrivate a febraio
-     few pillars (mono and poly)
-     few pillars with Mo (mono and poly) and Ag (mono) coating
-     Half Lens (1 inch )
-     Half Lens (esperimento BESSY, Scherbinin et al. )
-     Half Lens – Saratov
-     Cylindrical Lens – Saratov
-     2 Cylindrical Lens - IRO
-     1 Full Lens - IRO
-     2 CRL - Minsk
-     Acqusition Eelectronics:
-     Pre-amplifier, Shaper, MCA XGLab;
-     Electronics Exp. Dear (loan by group Siddharta);
-     HV for scintillator Ortec 3 KV;
-     Elettronics Ortec for acquisition by scintillator TSCA, counter with interface RS232;
-     Elettronics Ortec TSCA;
-     HV for scintillator Ortec 2 kV;
-     KUSB-3100 Keithley
-     Elettronics
-     Generatore di Funzione d'onda Tetronix ;
-     Generatore LV 4 canali;
-     Frequenzimetro TTL ;
-     Oscilloscopio digitale Tetronix;
-     Generatore LV lineare 240 AC- 240 DC;
-     Profilometro Laser Micro-Epsilon Luchsinger optoNCDT 1401
-     Sistemi Ottici e Movimentazioni
-     Controller Newport MM4006;
-     2 attuatori lineari CML12CCCL e schede per MM4006 Newport;
-     2 attuatori lineari CML12CCCL e schede per MM4006 Newport;
-     2 attuatori lineari CML25CCCL e schede per MM4006 Newport;
-     2 stage rotativi e schede per MM4006 Newport;
-     2 attuatori NSC-100 con controller Newport;
-     Controller generale NSC-100 Newport;
-     Adattatore RS232 NSC-100 Newport;
-     5 Movimentazioni XYZ Newport;
-     vari micrometri Newport;
-     2 stage rotativi manuali Newport;
-     Vari supporti con diverse dimensioni Newport;
-     Vari carrelli Newport;
-     2 iridi per laser Newport;
-     5 binari Newport
-     Varie
-     Sistema di pompaggio da vuoto Varian;
-     Sistema di pompaggio da vuoto EcoVide;
-     Desktop Acer;
-     Monitor Sony;
-     2 Monitor Lenovo;
-     1 laptop Acer TM 3040;
-     3 Scanner Epson;
-     Etichettatore Dymo;
-     Armadio anti-polvere
-     Software
-     1 licenza LabView 8.2;
-     1 licenza Fortran Compiler 9.1;
-     Sviluppo sistemi di acquisizione LabView per caratterizzazione Ottiche raggi X;
-     Sviluppo sistemi di acquisizione microXRF e TXRF;
-     PolyCAD;
-     1 licenza Kaleidagraph per Mac;
-     I pc  (1 Mac desktop e 2 laptop, 1 Mac e 1 Compaq);
-     1 Licenza per Image-Pro – per CCD Photonic Science

@ X-ray Diffraction Stage

-     X-ray diffractometer Seifert;
-     Radiation protected cabinet combined with safety electronics and power supply